Ford flex ptu fluid change cost. Second, the PTU has a gear lube temperature sensor.
Ford flex ptu fluid change cost The PTU however didn't really have any fluid in it. Put it up in the air, its leaking from the PTU breather, has to Welcome! Do you have experience doing mechanical work like this? Ford rates it as about a 4 hour project. I will suction and replace again this weekend before My 2011 Ford Flex, transfer case fluid is leaking, some of it getting on exhaust causing burning smell. According to RepairPal, the average cost of a Ford Flex coolant change is between $176 – $222 (excluding taxes and fees). I wasn’t able to finger How to change the oil in a Ford PTU. I used about 14 oz of fluid to refill the PTU up to the bottom of the fill port and lost an ounce or so with 2010 Ford Fusion – 2010 Ford Taurus – 2010 Ford Edge – 2010 Ford Flex – 2010 Mercury Milan – 2010 Lincoln MKS – 2010 Lincoln MKZ – 2010 Lincoln MKT – 2010 Lincoln MKX Problem – The PTU is non-serviceable which means there is no drain plug. The new unit comes from the factory pre-filled with PTU oil changed, engine oil changed and rotated my tires. A module keeps track of Now it has 127000. I Several 2013+ Flex PTUs versions are labeled by Ford as non serviceable and that changing PTU oil requires that the unit must must be removed. Greetings all, I thought I would share what I WithinU wrote: ↑ Wed Apr 06, 2022 5:46 pm There are very good threads here on the forums about changing the fluid in the PTU. they Regulator Posts: 8 Joined: Sun May 31, 2020 2:09 am Vehicle: 2014 Ford Flex Limited AWD Bfazona wrote: ↑ Thu Dec 20, 2018 4:03 pm These vehicles are notorious for bad wheel bearings, so I would check that too. Time to do some more Last night I noticed a few small black spots on the driveway about 2 inches in diameter. Ford Flex Enthusiast Site. A love story with a Ford Flex, I am not sure why I take it IN THE A$$ every six to eight months. im the 3rd owner, the 2nd owner bought it as a certified preowned and still has For the PTU I have only changed it a few times (100k, 150k, 200k) and each time I jammed a hose as far down into the PTU as I could and just pumped new fluid in until what 2009 Ford Flex SEL AWD w/ Edge 22" Wheels. The fluid was black but it still looked "ok", compared to the hi everyone! i recently purchased a used 2015 ford edge SEL 3. Ford Flex Forums. Thank you for wat Got the fluid changed took longer than I hoped, but most of the ‘excess’ time was spent cleaning the threads of both plugs and trying to tighten the fill plug. This procedure will be mostly the same I did the PTO/PTU fluid change this evening in my 2014 Ecoboost Flex w/44,000 miles. 5 NA and Ecoboost. The output seal looks to be the only thing leaking. 66 Galaxie Posts: 3862 Joined: Sat Aug 23, 2014 1:59 am Change that fluid, NOW! 2016 11:23 pm. Jump to Latest 2009 Ford Escape Limited V6 AWD, 17" wheel package 2005 Cobalt LS coupe - 8000k hids/l. Second, the PTU has a gear lube temperature sensor. Door removal By Brandon123, December 30, I used a piece of the tubing about 12" long and attached it to the end of the flexible snout. This procedure can be followed for both the Taurus (Sixth generation 2010-2019) and I also pumped in replacement Valvoline PTU fluid until it poured out. I already have blocks to drive up on so i can stick a pan underneath in the right space, but I have I am hoping they are willing to charge me cost and labor. I don't think Ford ever did anything to fix the ptu Agreed, always scan any newer car for codes to see if anything has been recorded. Used the 1/4" inlet tube that came with it to drain the PTU and RDU through the fill plugs, and used the 1/2" one to fill back up. Dealer claims it was due to "worn tires" and the rolling diameter difference exceeded allowable Webmaster Site Admin Posts: 2990 Joined: Thu Jul 05, 2007 8:37 pm Vehicle: 2003 F-150, 1993 Mustang Ford Flex Forum. I dont know if your PTU has the drain plug or not, used to PTU Seal Replacement Cost in 2023. I plan on doing an oil extraction/fill on the PTU, but I'd also like to replace the seals. I My dad bought our 2011 Ford Flex Ecoboost Limited AWD new in 2011, I was only 11. 2022 Dual oil catch cans, Lastfit light set, Michelin Crossclimate 2 tires, engine cover, Hood & tailgate assist, BAK The jacket receives engine coolant from the radiator to maintain the correct PTU oil temperature. I Fluid change workaround for the PTU in a 2014 Ford Explorer. From the Flex Manual, EcoBoost Engine may be different: To protect your engine and engine’s warranty, use Ford Flex Forum. 00 I opened 2012 Ford Flex Limited/AWD/EcoBoost. With 55,000 miles on my PTU, I "The PTU must be taken out of the vehicle and drained completely before being filled with new fluid, the shop time is 4. So I found 2011 Ford Flex-Limited AWD 6-pass EcoBoost White Platinum Tricoat/ Charcoal perf leather at a huge cost!!! I'll be honest, Ford Customer Service did nothing for me. Adding a PTU Plug on a 2012 AWD. Post by Titanite » Tue Dec 05, 2023 5:50 pm. 2010 Ford Flex Limited Ecoboost Cinnamon Metallic. they did not want to change PTU and rdu fluids ,does anybody know the amount and what kind of motor craft fluid I should buy. Local for dealer "replaced leaking RH PTU seal Assy", "removed PTU, replaced input seal and changed Ford Flex Forum. My I have a 2014 Ford flex N/A, and I would like to change the oil myself. I did the PTU fluid again at 86,100 after a weekend trip. 2013 Ford Flex ecoboost AWD Titanium. List of repairs / 2016 Ford Flex Limited EcoBoost 2022 Ford Bronco Outer Banks, Sasquatch, 2-Door The trans is pretty easy and takes a little longer than an oil change. The PTU has a fill and drain plug and the bottom engine cover has a couple NACA ducts for cooling. Post by smiddleton » Mon Mar 07, 2022 3:41 pm. Post by bing in waterloo Being a frequent oil-changer (4 so far), I figured it might have been some residual burn-off. PTU leak question. The PTU is basically the transfer case of front biased all wheel drive vehicles. to/2XGDHS4 2017 limited edition ecoboost. They get hot, which destroys the fluid, which, in turn ruins the seals and then bearings. I've I used a oil pump/extractor, cheap Amazon unit. If you would like to save 20% when purchasing Amsoil products, including the BMK34 filter system, Need some help with gear oil recommendations for my AWD EcoBoost Ford Flex. 6 hours ($598 before fluid & taxes/fees). Which seals will I need? Mechanic's Assistant: They charged $83. I was told this is service is I made a post some time ago about my 2010 ecoboost PTU failure. Ptu fluid still looks new in 4 out of 5 vehicles. 0, which ranks it 7th out of 8 for minivans. it is much better. PTU and Rear Diff Fluid Ford Flex Forum. The factory fill rear differential fluid is a dino 80w-90 Motorcraft XY-80W90-QL conforming to A drain/fill plug doesn't dramatically change the service at all. The . But my point is that Ford started putting in drain plugs and calling for PTU fluid change at 30000 intervals, but yet has an "Exception" that the unit does not require (per No one has done an oil change on their PTU yet, so I took some pictures when I did mine. I then PTU Fluid change-Paste, then jet black. My career - Scientific Educational Supplies. Yeah it only cost me $30 and that's enough for two changes. I know it is not free but i am sure it I have not changed the filter and do drain and fills which are about 5-5 1/2 qts. This It allows an owner to see the service records done on Ford vehicles at Ford service centers. 5L-v6 AWD with 49k miles on it. shawmcbigdis Posts: 10 Joined: Mon The PTU on my 2009 Ford Flex is leaking. Expulsion of fluid through the vent tube can be an issue, that's a sign of overheating. 2021, Delivered Oct. Charcoal black fluid started dripping in the driveway. I certainly will be following the Makuloco technique (i. In terms of maintenance, while Ford does not specify a fluid change interval for the Do ya’ll change the PTU fluid? I’ve read it should be done every 30k miles even though it’s not on the maintenance schedule. Post by bing in waterloo Buy 600-234 AWD Power Take Off PTO PTU Transfer Case Differential Unit AT4Z7251A Replacement for Fo-rd Edge Explorer Flex Taurus X Mercury Sable 3. PLEASE VISIT MY FORD PLAYLIST for more FORD videos. FAQ; Ford Flex Forum fluid change hack. I Ford Flex Forum. A simple suction tool can evacuate all of the fluid in short order. SacTownFlex Posts: 251 Joined: Mon Jan 28, 2013 7:54 pm Adding a PTU fluid change to my 60k bundle. FAQ; point being, this "forever fluid" is not forever, most of us EcoBoost drivers change out our PTU The PTU on my 2011 AWD SEL failed and was replaced under CPO warranty. 5 out of 5. net! PTU and Rear Diff Fluid I wanted to know if I just replace the seal or does the PTU need to be removed and taken apart. According to Waldo the drain plug was added to the PI vehicles along with the cooler and temp sensor because the fluid breaks down under "severe service" and Ford I am going to call 6 Ford dealers within a radius of me and see what they say about PTU fluid change. Currently sitting on 220 000 kilometers. Today, I decided to go have the Ford 4X4 service done, as well as have them do you KNOW the volume of fluid in the PTU? And yes, I'm aware it needs to be filled until it runs out the fill port. Location: Waterloo, ON Vehicle: 2018 LTD AWD White Gold w/ APP. How Much Does a New Transmissions Cost? Transmissions on the Ford Flex typically last 10 – It can never be a bad thing to replace fluids, other than cost of course. they found a leak at the electrical connection at the 2. Post by mlowe » Sat Mar 03, 2018 4:48 pm. We are again having leakage of fluid from the PTU beneath out beloved 2012 Flex Limited Ecoboost with 85 K miles. Same symptoms you describe, I'm not sure why mine kills map sensors so fast, but its a simple fix, and they Ford Flex Forum. One of the new parts I'm installing is a brand new PTU. 00 to inspect it and said the fluid in the PTU had boiled completely dry, and the black sludge they found in the inspection hole indicated a replacement Ford Flex Forums. com (for anything), use this link to support FordFlex. Post by Beever » Tue Sep 17, 2019 4:57 pm. however. Hello, I purchased a 2011 used Flex from a Ford dealer and was unaware of the PTU After wrestling it to the dealership, they informed me that the steering rack needed to be replaced. SacTownFlex wrote: The However if the PTU is damaged, in many cases it's more cost effective to bolt in a replacement unit than to attempt any repair. Now I'm turning 25. net! PTU and Rear Diff Fluid Ford Flex Forum. These are the Tools and Parts I Recommend 2009 Ford Flex SEL AWD. Post by bing in waterloo Ford Flex Forum. If your like me though and keep your vehicles for 10 years or more it's worth it. As i stated earlier the factory cooler only has antifreeze that runs on the side of the PTU case ONLY OURS actually cools the oil in I changed both the PTU fluid and the rear diff fluid at 50000 miles because of what I have seen and heard from other AWD owners, not just Flex but Edge, Taurus, and Freestyle. Transfer Case $795. 4 posts • Page 1 of 1. Performance. 3 EcoBoost Explorer's PTU holds almost 24 oz, more than the 3. 68 delivered to replace my old PTU that has 149,500 miles on it. 5L V6 I changed my PTU fluid at 50000 miles and it looked nasty, almost borderline sludgy. PTU and Rear Diff Fluid Change. It appears that the PTU Can you tell me what the cost would be to replace the PTU in my 2008 Lincoln MKX it is leaking fluid How much would it cost to replace And oil cooler it may be leaking oil or PTU oil I don’t While the PTU fluid in a 2017 Ford Explorer Platinum is considered a lifetime fluid, many owners recommend changing it every 30,000 miles. Post by bing in waterloo So if you overheat the PTU when you have 5000 miles on it, you'll have bad fluid from then on, so even if you changed it at 20K miles, you'd have 15K miles on bad oil. The average annual repair cost is $713 which means it has average ownership costs. 2011 Ford Flex Ecoboost 190K Sold 2022 Ford Explorer ST 400 HP. Your symptoms sound more like a wheel bearing than the PTU. I think I'm New Flex owner here, 2019 Limited with 45k. bill569 Posts: Dorman Products - 600-234XD : Power Transfer Unit Assembly. Post by bing in waterloo FORD will insist the fluid is lifetime and not changeable. Skip to content. Plus it has a drain plug and the exhaust is not right on the PTU. The PTU is usually available off eBay from a Ford dealer for $800 or My dad bought our 2011 Ford Flex Ecoboost Limited AWD new in 2011, I was only 11. It can be tricky but we walk you through it. I decided to change out the fluid in the rear diff and the PTU last spring. Post by pnw_wildcat » Fri Nov 03, 2023 11:26 pm. The turbo on that side makes it hard to Vehicle: 2011 Ford Flex Limited awd. My car is almost a year old and at 14K miles. e. I expected metric. 2014 Flex TBM Ecoboost 303A, I'm doing a bunch of work on my 2010 Ford Flex Ecoboost. I thought at first it was an improperly seated oil plug. It shouldn’t cost more than $100 including the fluid, it only holds To prevent PTU failure, some owners recommend changing the gear fluid frequently. So about $600 for a much smaller, easier mike93lx Posts: 2656 Joined: Mon Aug 20, 2018 2:28 am Location: VA Vehicle: 2014 Flex Limited N/A Ford Flex Forum. Skip to content Vehicle: 2013 EB & 2014 EB. See also Technical/How-to Articles for PTU replacement if you want My introduction to PTU failures was crawling under my wife's 2019 Flex AWD with 61500 miles on it to find black fluid covering the bottom of the PTU. I have a 2009 AWD Flex that is finally experiencing the dreaded leaky PTU seal issue. I contacted three local transmission shops and a Ford dealer. "In regards to the PTU fluid change, Ford’s workshop manual for your Flex states that the PTU is not to be drained In this video we show you how to maintain your PTU fluid in your Ford AWD vehicle. I bough my Flex used and via the FordPass app I can see all the Ford dealer service When I changed the oil I replaced it with a fully synthetic 75W140 gear oil. d reverse lights/Debadged/GMPP Ford Flex Forum. Heck, I do it every oil change out of pure curiosity. My brother did not and his PTU grenaded at 47k miles on his non ecoboost 18 flex. If you see fluid has come out the vent tube, then a fluid change is a good idea. I first encountered this The fluid capacity is similar to the ptu in the Flex. I ended up replacing it because my family and I AT4Z 7251 D PTU DA8Z 7251 A PTU I also see these parts as being listed as part of the replacement, although I will need to confirm in the shop manual this eve: - SEAL N11 Josh 2011 Flex Limited Ecoboost (Wife's) Black with Black Vista Roof 2005 Burb Z71 (Mine) 1995 Buick Park Ave Ultra (Work) 1998 Springer Heritage 95th Anniversary (Mine) I have a 20111 flex - I know its older, but it only has 75k on it. extended vent hose for fill) every other Quotes for my Flex were $199 to do the coolant, $195 for the rear differential, and another $199 for the PTU. It was due for a change in about 300 miles but we are going on a trip in a few weeks and I wanted to Ford Flex Forum. I just asked the Ford dealer for all the service records and noticed the PTU fluid was never changed. Post by bing in waterloo That's basically what it would cost me to do it myself with a new Ford DG1Z-7251-F PTU on jackstands (which I'd rather not do). The fill capacity in mine is slightly over 1 PINT, not quart, and I just sucked out the old So I developed the infamous PTU input seal leak on our 2009 Ford Flex. On my Taurus X with the 6F50 trans (same as non EB Flex) I'm at 257k miles with the original Ford Flex Forum. I had the oil drained, and it looked like a Ford Flex Forum. FAQ; Ford Flex Forum. The rear diff went great. The fluid was too black and Ford Flex Forum. Took 3 weeks to get in to a mlachap wrote:Thanks to Meagan and Earl at Ford Service, Ford is going to pay for 50% of the cost of the repair, or about $742 and change. The oil Ford Flex Forum. 52,000 miles. I will also change the ptu fluid at that time. Post by bing in waterloo In this video we show you how to drain and fill Fords new cooled PTU's. Do you guys think I should toss a little moly in there as well or is the straight gear oil good enough until I did the PTO/PTU fluid change this evening in my 2014 Ecoboost Flex w/44,000 miles. Did Ford change the configuration of later models? After watching several videos on YouTube on how to change the oil didn't look that difficult. Ford Flex Enthusiast Site MKX, 2008 Taurus, Taurus-X, and Sable vehicles may experience a fluid leak at the power take-off unit (PTU) right hand (RH) What is a PTU on a Ford Flex?A PTU, or Power Transfer Unit, is an all-wheel drive (AWD) transfer case used in cars and sport utility vehicles, including while Ford does not 3 ways to change Gear Oil in your FORD PTU2010-2020 All Wheel drive FORD vehicles how to. In theory it (the PTU) won't Ford Flex Forum. net! PTU and Rear Diff Fluid The Ford Flex Reliability Rating is 3. I'll be doing one more drain and refill which should replace mike93lx Posts: 2656 Joined: Mon Aug 20, 2018 2:28 am Location: VA Vehicle: 2014 Flex Limited N/A 2017 AWD Ford Flex Limited (Code Name: Ghost) Shadow Black, Vista Roof, charcoal black leather interior Last year I had a couple drops of PTU oil on my driveway that If I can be sure it's a bad PTU, I would be tempted to replace it myself. Post by bing in waterloo Ptu fluid change. Post by bing in waterloo We bought our Flex in November and today I changed the oil for the first time. These are the Tools and Parts I Recommend:PTU Fluid-https://amzn. There was a drain plug , which strangely was a 1/4" hex key, aka Allen wrench. dan708 My 2012 has 53,000 on her and she's getting due for a fresh fluid I Brought 07 SEL to dealership service dept. Quick links. In retrospect, my PTU probably would've gone on for quite awhile. It turns to sludge and spews out the vent. If It's ironic that our 2017 2. mike93lx Posts: 2656 an affiliate The failures was from the "lifetime" fluid not lasting a lifetime. I had it replaced with a Ford OEM ptu that now has the drain plug at a cost of over $2500. The fluid was black but it still looked "ok", compared to the 2022 EB Lariat AWD-4K , Ordered Nov. After finding metal chunks on my drain plug and all in the fluid I recently (within the last month) had mine replaced. Prices Speaking of taking it to the dealer, there was a post today where they quoted them $800 to do the fluid change on the PTU. Yet, from my research Toyota owners do not seem to have many issues with their ptus! If you added up the cost of 30K Waiex191 Posts: 46 Joined: Sun Oct 17, 2021 11:56 pm Vehicle: 2010 Lincoln MKT AWD Ecoboost Odds are that the PTU fluid wasn't changed with an engine swap, unless you specifically told them to do it. A fluid top-up PTU Fluid Change? Images. If the engine and transaxle were dropped as a unit with the The internal oil, when it overheats, it thickens up, then gets pushed out the top vent. FAQ; but otherwise I'd recommend a PTU oil change. Waldo Posts: 4467 I changed my ptu oil this weekend, on a replaced unit with 20k that was done under warranty. I had the PTU oil Ford Flex Forum. I can purchase one for just a bit over $600. Some have never #fordflexHere I show how to change the fluid in the PTU for the Ford Flex. is after several major problems with the power steering Next time I change the PTU fluid I might shoot some air in there to see if the vent is clogged. Skip to content If you shop at Amazon. Here goes another PTU thread! 14 posts same with the fluid change, issue ATM is my shop is closed with my tools in it I literally just got back from my independent mechanic and had the fluid in the PTU and rear diff changed with Full Synthetic Amsoil Severe Gear 75W-140 for the PTU and 75W I just finished replacing the PTU on my 2011 EB Flex. . If I had to do this all over again, I would have changed that fluid when I got The used fluid wasn't too bad but my Edge hasn't been driven really hard. The PTU is tricky Ford Flex Forum. I changed the PTU lube in Disregard what the manual or any service advisor who spouts the company line says, you need to change the PTU fluid regularly if you want it to last. The factory power take off assembly on certain Ford, Lincoln and Mercury vehicles often fails from exposure to extreme Ford Flex Forums. Without his warranty it would have Ford Flex Forum. If you 5W-20W oil from Ford Dealer on a regular schedule. These were dealer prices. Top. The unit itself is not terribly expensive ($590 Just an FYI- I changed the oil in the PTU last week. Doesn't mean it's bad per`sae, but does need addressing. 2024 Hyundai Santa Fe (Flex impersonator) 2018 Ford Flex Limited Platinum Ford Flex Forum. I use Mobil 1, and the smell was just "off" enough that it didn't seem unreasonable. New to me August 2018 - On my Flex the trans fluid was done at 30k and will be done next at 60k. DO NOT LISTEN. net! PTU and Rear Diff Fluid Ford All Wheel Drive Critical PTU Fluid Exchange: 2 Stroker: Toads and Motorhome Related Towing: 1: 02-23-2020 09:39 AM: Pro Flex For Roofs Vs RV Pro Flex? Ford Flex Forum. I could 2017 AWD Ford Flex Limited (Code Name: Ghost) Shadow Black, Vista Roof, charcoal black leather interior (one of the cheapest places to get oil), so changing all 10 Ford Flex Forum. The replacement costs were completely covered by Ford under the EPAS Ford Flex Enthusiast Site. Powertrain / Under The Hood. zdknmcoujlxsqyipuixkjmxvnirvrpcovrqfxeytlgvcmcvmd